Cite as: Cold Spring Harb. Protoc.; 2008; doi:10.1101/pdb.prot4722

This Protocol
Right arrow Full Text
Right arrow Update/discuss this protocolDiscussion icon
Right arrow Alert me when this protocol is cited
Right arrow Alert me when comments are published
Right arrow Alert me if a correction is posted
Services
Right arrow Similar protocols in this database
Right arrow Alert me to new releases of protocols
Right arrow Save to Personal Folders
Right arrow Download to citation manager
Right arrow Printer-friendly versionPrinter-friendly version
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simpson, R. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Simpson, R. J.
Related Collections
Right arrow Cell Biology, general
Right arrow Protein Identification and Analysis
Right arrow Molecular Biology, general
Right arrow Proteins and Proteomics, general
Right arrow Protein Classification and Structure Prediction
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
BSN globe

protocolProtocol

Quantifying Protein by Bicinchoninic Acid

Richard J. Simpson

This protocol was adapted from "Techniques," Appendix 2, in Proteins and Proteomics by Richard J. Simpson. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, NY, USA, 2003.


INTRODUCTION

This protocol describes a method of quantifying protein that is a variation of the Lowry assay. It uses bicinchoninic acid (BCA) to enhance the detection of Cu+ generated under alkaline conditions at sites of complexes between Cu2+ and protein. The resulting chromophore absorbs at 562 nm. This technique is divided into three parts: Standard Procedure, Microprocedure, and 96-Well Microtiter Plate Procedure. For each procedure, test samples are assayed in parallel with protein standards that are used to generate a calibration curve, and the exact concentration of protein in the test samples is interpolated. The standard BCA assay uses large volumes of both reagents and samples and cannot easily be automated. If these issues are important, the Microprocedure is recommended. This in turn can be adapted for use with a microplate reader in the 96-Well Microtiter Plate Procedure. If the microplate reader is interfaced with a computer, more than 1000 samples can be read per hour.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
CSH ProtocolsHome page
R. J. Simpson
Estimation of Free Thiols and Disulfide Bonds Using Ellman's Reagent
CSH Protocols, September 1, 2008; 2008(10): pdb.prot4699 - pdb.prot4699.
[Abstract] [Full Text]