Cite as: Cold Spring Harb. Protoc.; 2006; doi:10.1101/pdb.ip16

This Protocol
Right arrow Full Text
Right arrow Update/discuss this protocolDiscussion icon
Right arrow Alert me when this protocol is cited
Right arrow Alert me when comments are published
Right arrow Alert me if a correction is posted
Services
Right arrow Similar protocols in this database
Right arrow Alert me to new releases of protocols
Right arrow Save to Personal Folders
Right arrow Download to citation manager
Right arrow Printer-friendly versionPrinter-friendly version
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Verveer, P. J.
Right arrow Articles by Bastiaens, P. I.H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Verveer, P. J.
Right arrow Articles by Bastiaens, P. I.H.
Related Collections
Right arrow Protein: Protein Interactions, general
Right arrow Biophysical Approaches
Right arrow Imaging/Microscopy, general
Right arrow Proteins and Proteomics, general
Right arrow Protein Imaging, general
Right arrow Imaging of Protein: Protein Interactions
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
Legend icon

information_panelInformation Panel

An Experimental Setup for Frequency Domain FLIM

Peter J. Verveer, Oliver Rocks, Ailsa G. Harpur, and Philippe I.H. Bastiaens

This information panel was adapted from "Imaging Protein Interactions by FRET Microscopy," Chapter 32, in Protein-Protein Interactions (ed. Golemis and Adams). Cold Spring Harbor Laboratory Press, Cold Spring Harbor, NY, USA, 2005.

The first 100 words of the full text of this article appear below.

The following are key elements of a frequency domain fluorescence lifetime imaging system: (1) a standing wave acousto-optic modulator (SW-AOM) that modulates the intensity of the excitation light source at high frequency and (2) a frequency mixing device, such as an image intensifier, to perform phase-sensitive detection of the fluorescence emission. Figure 1 shows a single-frequency FLIM configuration. The instrument is based around a vibrationally isolated, inverted microscope (e.g., Zeiss Axiovert 135 TV). The basic light source requirement is an argon laser with sufficient output power (>100 mW per line). The 457-nm, 488.0-nm, and 514.5-nm lines are ideal for excitation . . . [Full Text of this Article]

-->
-->


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?