Poly-L-ornithine-coated plates
MATERIALS
METHOD
-
1. Prepare 1.5-mg/mL (100X) aliquots of poly-L-ornithine hydrochloride by diluting in H2O. Store at −20°C.
-
2. Prepare coated plates:
-
To coat 6-well plates for biochemistry:
-
i. Dilute the 100X poly-L-ornithine to 1X in sterile 1X PBS, and pipette enough of the solution to cover the surface of each well. Incubate plates overnight at 37°C.
-
ii. The next day, aspirate the coating solution and wash three times with H2O, making sure the H2O thoroughly fills each well. Air dry in a tissue culture hood until no H2O remains.
-
iii. Store covered in foil at 4°C if the plate is not to be used immediately.
-
To coat 24-well plates for morphology assays:
-
iv. Sterilize a packet of 12-mm coverslips by rinsing for several hours in 70% ethanol and drying overnight under the UV light of the tissue culture hood.
-
v. Place one coverslip in each well of the 24-well plate, add 0.5 mL of 1X poly-L-ornithine coating solution (diluted as in Step 2.i) per well, and follow the incubation/rinsing procedure described in Step 2.ii, using at least 1 mL of H2O per well.
-