Table

Table 1. Oligonucleotides and sequences

Oligo ID Sequencea
IS1_adapter.P5 A*C*A*C*TCTTTCCCTACACGACGCTCTTCCG*A*T*C*T
IS2_adapter.P7 G*T*G*A*CTGGAGTTCAGACGTGTGCTCTTCCG*A*T*C*T
IS3_adapter.P5+P7 A*G*A*T*CGGAA*G*A*G*C
IS4_indPCR.P5 AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTT
IS5_reamp.P5 AATGATACGGCGACCACCGA
IS6_reamp.P7 CAAGCAGAAGACGGCATACGA
IS7_short_amp.P5 ACACTCTTTCCCTACACGAC
IS8_short_amp.P7 GTGACTGGAGTTCAGACGTGT
BO1.P5.F AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATCT-Pho
BO2.P5.R AGATCGGAAGAGCGTCGTGTAGGGAAAGAGTGTAGATCTCGGTGGTCGCCGTATCATT-Pho
BO3.P7.part1.F AGATCGGAAGAGCACACGTCTGAACTCCAGTCAC-Pho
BO4.P7.part1.R GTGACTGGAGTTCAGACGTGTGCTCTTCCGATCT-Pho
BO5.P7.part2.F ATCTCGTATGCCGTCTTCTGCTTG-Pho
BO6.P7.part2.R CAAGCAGAAGACGGCATACGAGAT-Pho
a5′-3′; * indicates a PTO bond; Pho indicates a 3′-phosphate.
See Supplemental Material (Indexing_Oligo_Sequences.doc) for indexing oligo sequences.
All oligos (HPLC purified, 0.2 μmol synthesis scale) should be dissolved in TE or H2O. Oligos 1-3 should be dissolved to 500 μM, oligos BO1-BO6 to 200 μM, and all other oligos to 10 μM. The indexing oligos should be transferred to a 96-well plate to allow for multichannel pipetting. HPLC purification can potentially introduce cross-contamination among indexing oligos. It is therefore important to (1) instruct the company to properly wash the HPLC column before loading a new oligo and (2) synthesize the oligos in a different order than listed here. This makes sure that cross-contamination induced during synthesis can be detected after sequencing by the appearance of index sequences that were not used in the experiment. When designing index sequences, the following criteria were taken into account: (1) Index sequences differ by at least three substitutions. This reduces the chance of converting one index into another by sequencing and amplification errors. (2) Indexes cannot be converted into one another by deleting the first base, which is the only insertion/deletion error common with Illumina sequencing. (3) Index sequences do not contain three or more identical bases in a row to ensure that they can be differentiated from artifact sequences. (4) Stretches of bases illuminated with the same laser (ACA, CAC, GTG, and TGT) are avoided. Software for designing alternative index sequences, for example, with a length of 6 or 8 nt, and for selecting appropriate subsets for pooling is provided at http://bioinf.eva.mpg.de.
No Related Web Pages
| Table of Contents

This Article

  1. doi:10.1101/pdb.tab195448 Cold Spring Harb Protoc 2010: pdb.tab195448-

Article Category

  1. Table

Personal Folder

  1. Save to Personal Folders

Updates/Comments

  1. Alert me when Updates/Comments are published

Related Content

  1. Related Web Pages

Share