Table 1.

Resistance-dependent poring and driving pulse parameters for mRNA electroporation

Resistance (Ω) Poring Pulse / Driving Pulse Parameters
Volt (V) Length (msec) Interval (msec) Repeat count
200 10 / 3 50 / 50 50 / 50 3 / 10
200–400 20 / 5 50 / 50 50 / 50 3 / 10
400–600 35 / 7 50 / 50 50 / 50 3 / 10
600–1000 50 / 10 50 / 50 50 / 50 3 / 10